Power Factor Correctors Toroidal T18 |
POWER MAGNETICS (OLD) | Back |
|
- Designed for use in off-line AC/-DC pre-regulators circuits for
switching power converters applications.
- Low cores loss and high flux density.
- Auxiliary winding optional.
|
FPN |
Mounting / PCB Layout |
L (mm) max. |
W (mm) max |
H (mm) max |
Auxiliary Winding/L1 Ratio |
DCR(mW)1 max. |
L(mH)1,2 |
L1 ST-FN |
AUX ST-FN |
l@ 80%L (A DC) |
l@ 65%L (A DC) |
l@ 50%L (A DC) |
l@ 30%L (A DC) |
 T18047 |
V/FIG.1 |
57.15 |
31.75 |
54.86 |
... |
34 |
200 |
1 - 2 |
--- |
14.46 |
23.67 |
32.87 |
52.59 |
 T18048 |
V/FIG.1 |
57.15 |
31.75 |
54.86 |
... |
34 |
200 |
1 - 2 |
--- |
14.46 |
23.67 |
32.87 |
52.59 |
 T18050 |
V/FIG.3 |
55.88 |
29.21 |
55.88 |
... |
50 |
200 |
1,2 - 6,5 |
--- |
14.69 |
24.04 |
33.39 |
53.42 |
 T18063 |
V/FIG.6 |
55.88 |
30.48 |
57.15 |
... |
23 |
135 |
2 - 5 |
--- |
18.80 |
30.77 |
42.73 |
68.37 |
 T18035 |
V/FIG.2 |
58.42 |
53.34 |
63.50 |
... |
40 |
279 |
7,6,5 - 2,3,4 |
--- |
13.06 |
21.37 |
29.68 |
47.48 |
 T18034 |
V/FIG.2 |
58.42 |
53.34 |
63.50 |
... |
100 |
477 |
7,6 - 2,3 |
--- |
10.00 |
16.37 |
22.73 |
36.37 |
 T18037 |
V/FIG.4 |
55.88 |
53.34 |
63.50 |
... |
327 |
1341 |
2 - 1 |
--- |
5.91 |
9.68 |
13.44 |
21.50 |
 T18040 |
V/FIG.5 |
57.91 |
31.75 |
59.94 |
... |
250 |
1620 |
2 - 5 |
--- |
5.37 |
8.71 |
12.21 |
19.54 |
*Contact FALCO for detailed specifications
- AMBIENT TEMPERATURE TEST AT 25°C
- TEST AT 20KHz and 0.25V.MINIMUM INDUCTANCE.
|
|
|
- Designed for use in off-line AC/-DC pre-regulators circuits for
switching power converters applications.
- Low cores loss and high flux density.
- Auxiliary winding optional.
|
FPN |
Mounting / PCB Layout |
L (mm) max. |
W (mm) max |
H (mm) max |
Auxiliary Winding/L1 Ratio |
DCR(mW)1 max. |
L(mH)1,2 |
L1 ST-FN |
AUX ST-FN |
l@ 80%L (A DC) |
l@ 65%L (A DC) |
l@ 50%L (A DC) |
l@ 30%L (A DC) |
 T18029 |
V/FIG.1 |
54.10 |
52.32 |
63.50 |
... |
35 |
310 |
2,3,5,6 - 13,12,10,9 |
--- |
17.41 |
28.49 |
39.57 |
63.31 |
 T18011 |
V/FIG.2 |
62.23 |
54.61 |
62.23 |
... |
38 |
383 |
4 - 11 |
--- |
15.67 |
25.64 |
35.61 |
56.98 |
 T18028 |
V/FIG.3 |
54.86 |
52.32 |
63.50 |
... |
40 |
383 |
12,10,9 - 3,5,6 |
--- |
15.67 |
25.64 |
35.61 |
56.98 |
 T18036 |
V/FIG.4 |
58.42 |
53.34 |
63.50 |
... |
120 |
675 |
2 - 4 |
--- |
11.90 |
19.47 |
27.05 |
43.27 |
 T18016 |
V/FIG.5 |
57.00 |
52.50 |
63.50 |
... |
114 |
693 |
4,3 - 1,2 |
--- |
11.61 |
18.99 |
26.38 |
42.21 |
 T18015 |
V/FIG.5 |
57.00 |
52.50 |
63.50 |
... |
118 |
828 |
4,3 - 1,2 |
--- |
10.68 |
17.48 |
24.28 |
38.85 |
*Contact FALCO for detailed specifications
- AMBIENT TEMPERATURE TEST AT 25°C
- TEST AT 20KHz and 0.25V.MINIMUM INDUCTANCE.
|
|
|
- Designed for use in off-line AC/-DC pre-regulators circuits for
switching power converters applications.
- Low cores loss and high flux density.
- Auxiliary winding optional.
|
FPN |
Mounting / PCB Layout |
L (mm) max. |
W (mm) max |
H (mm) max |
Auxiliary Winding/L1 Ratio |
DCR(mW)1 max. |
L(mH)1,2 |
L1 ST-FN |
AUX ST-FN |
l@ 80%L (A DC) |
l@ 65%L (A DC) |
l@ 50%L (A DC) |
l@ 30%L (A DC) |
 T18046 |
V/FIG.1 |
54.61 |
26.67 |
52.07 |
... |
12 |
97 |
1 - 2 |
--- |
12.21 |
19.84 |
27.47 |
45.79 |
 T18031 |
V/FIG.2 |
57.15 |
27.18 |
56.39 |
... |
45 |
303 |
2 - 5 |
--- |
6.84 |
11.11 |
15.38 |
25.64 |
 T18012 |
V/FIG.10 |
60.00 |
34.00 |
59.00 |
... |
... |
303 |
1,2,3 - 6,5,4 |
--- |
6.84 |
11.11 |
15.38 |
25.64 |
 T18002 |
H/FIG.3 |
58.42 |
58.42 |
32.26 |
... |
25 |
314 |
1 - 2 |
--- |
6.33 |
10.29 |
14.24 |
23.74 |
 T18032 |
V/FIG.4 |
57.15 |
31.75 |
54.86 |
54:4:3 |
25 |
314 |
2 - 5 |
1,3-6,4 |
6.33 |
10.29 |
14.24 |
23.74 |
 T18001 |
H/FIG.5 |
53.34 |
53.34 |
29.97 |
... |
45 |
540 |
1 - 2 |
--- |
5.10 |
8.29 |
11.48 |
19.13 |
 T18057 |
V/FIG.6 |
57.15 |
32.51 |
63.50 |
... |
44 |
594 |
2 - 5 |
--- |
4.88 |
7.94 |
10.99 |
18.31 |
 T18010 |
V/FIG.7 |
55.88 |
28.70 |
55.88 |
73:4 |
95 |
675 |
1 - 3 |
4-2 |
4.68 |
7.61 |
10.54 |
17.56 |
 T18025 |
V/FIG.7 |
55.88 |
28.70 |
55.88 |
73:5 |
95 |
645 |
1 - 3 |
4 - 2 |
4.68 |
7.61 |
10.54 |
17.56 |
 T180A9 |
V/FIG.7 |
55.88 |
28.70 |
55.88 |
... |
95 |
675 |
1 - 3 |
--- |
4.68 |
7.61 |
10.54 |
17.56 |
 T18A25 |
H/FIG.7 |
63.50 |
63.50 |
31.75 |
73:5 |
95 |
645 |
4 - 1 |
3-2 |
4.68 |
7.61 |
10.54 |
17.56 |
 T18056 |
H/FIG.8 |
55.88 |
55.88 |
31.75 |
... |
63 |
702 |
1 - 2 |
--- |
4.50 |
7.31 |
10.12 |
16.87 |
 T18060 |
V/FIG.6 |
57.15 |
32.51 |
63.50 |
... |
85 |
981 |
2 - 5 |
--- |
3.80 |
6.17 |
8.55 |
14.24 |
 T18053 |
V/FIG.6 |
57.15 |
32.51 |
63.5 |
... |
135 |
1098 |
2 - 5 |
--- |
3.598 |
5.85 |
8.10 |
13.49 |
 T18058 |
V/FIG.6 |
57.15 |
32.51 |
63.5 |
... |
98 |
1215 |
2 - 5 |
--- |
3.42 |
5.56 |
7.69 |
12.82 |
 T18009 |
V/FIG.9 |
55.88 |
28.70 |
55.88 |
104:3 |
192 |
1315 |
1 - 2 |
3 - 4 |
3.29 |
5.34 |
7.40 |
12.33 |
 T18055 |
V/FIG.6 |
57.15 |
32.51 |
63.5 |
... |
292 |
1746 |
2 - 5 |
--- |
2.85 |
4.63 |
6.41 |
10.68 |
 T18059 |
V/FIG.6 |
57.15 |
32.51 |
63.5 |
... |
176 |
2052 |
2 - 5 |
--- |
2.63 |
4.27 |
5.92 |
9.86 |
*Contact FALCO for detailed specifications
- AMBIENT TEMPERATURE TEST AT 25°C
- TEST AT 20KHz and 0.25V.MINIMUM INDUCTANCE.
|
|
|
- Designed for use in off-line AC/-DC pre-regulators circuits for
switching power converters applications.
- Low cores loss and high flux density.
- Auxiliary winding optional.
|
FPN |
RoHS Part Number |
Mounting / PCB Layout |
L (mm) max. |
W (mm) max |
H (mm) max |
Auxiliary Winding/L1 Ratio |
DCR(mW)1 max. |
L(mH)1 min. |
Freq, (KHz) |
Volt. (V) |
L1 ST-FN |
AUX ST-FN |
l@ 80%L (A DC) |
l@ 65%L (A DC) |
l@ 50%L (A DC) |
l@ 30%L (A DC) |
 T18030 |
 T18L30 |
V/FIG.1 |
54.61 |
53.34 |
57.15 |
... |
85 |
594 |
1 |
0.25 |
2 - 5 |
--- |
6.84 |
11.11 |
15.38 |
25.64 |
 T18041* |
|
V/FIG.2 |
55.88 |
55.12 |
70.87 |
54:4:3 |
55 |
708 |
10 |
0.30 |
3,4 - 5,6 |
1,7 - 2,8 |
6.33 |
10.29 |
14.24 |
23.74 |
*Mounting drawing is only for reference & paper phenolic is used as base
Contact FALCO for detailed specifications for P dimension
- AMBIENT TEMPERATURE TEST AT 25°C
|
|
|
- Designed for use in off-line AC/-DC pre-regulators circuits for
switching power converters applications.
- Low cores loss and high flux density.
- Auxiliary winding optional.
|
FPN |
Mounting / PCB Layout |
L (mm) max. |
W (mm) max |
H (mm) max |
Auxiliary Winding/L1 Ratio |
DCR(mW)1 max. |
L(mH)1,2 |
L1 ST-FN |
AUX ST-FN |
l@ 80%L (A DC) |
l@ 65%L (A DC) |
l@ 50%L (A DC) |
l@ 30%L (A DC) |
 T18005 |
V/FIG.1 |
60.00 |
70.00 |
60.50 |
... |
38 |
910 |
1,2,3,4 - 8,7,6,5 |
--- |
6.84 |
11.11 |
15.38 |
25.64 |
*Contact FALCO for detailed specifications
- AMBIENT TEMPERATURE TEST AT 25°C
- TEST AT 20KHz and 0.25V.MINIMUM INDUCTANCE.
|
|
|
- Designed for use in off-line AC/-DC pre-regulators circuits for
switching power converters applications.
- Low cores loss and high flux density.
- Auxiliary winding optional.
|
FPN |
Mounting / PCB Layout |
L (mm) max. |
W (mm) max |
H (mm) max |
Auxiliary Winding/L1 Ratio |
DCR(mW)1 max. |
L(mH)1,2 |
L1 ST-FN |
AUX ST-FN |
l@ 80%L (A DC) |
l@ 65%L (A DC) |
l@ 50%L (A DC) |
l@ 30%L (A DC) |
 T18044 |
H/FIG.1 |
60.96 |
60.96 |
81.28 |
... |
35 |
279 |
1 - 2 |
--- |
14.24 |
23.15 |
32.05 |
53.42 |
*Contact FALCO for detailed specifications
- AMBIENT TEMPERATURE TEST AT 25°C
- TEST AT 20KHz and 0.25V.MINIMUM INDUCTANCE.
|